GP100W電極/GP-100W
產(chǎn)品概述
GP100W電極(型號(hào):GP-100W)是一款專為污水處理及工業(yè)過(guò)程設(shè)計(jì)的pH測(cè)量電極,集成溫度補(bǔ)償功能,適用于復(fù)雜水質(zhì)環(huán)境下的長(zhǎng)期在線監(jiān)測(cè)。其采用環(huán)形聚四氟乙烯液接界和固態(tài)電解質(zhì)技術(shù),有效防止介質(zhì)污染與電極中毒,同時(shí)具備快速響應(yīng)和高穩(wěn)定性特點(diǎn)。電極外殼采用耐腐蝕材質(zhì),適配標(biāo)準(zhǔn)3/4英寸螺紋安裝,支持管道或護(hù)套管固定,滿足多樣化工業(yè)場(chǎng)景需求。
英文介紹:The GP100W electrode (Model: GP-100W) is a pH measurement electrode designed for wastewater treatment and industrial processes, featuring integrated temperature compensation for accurate monitoring in complex liquid environments. With a ring-shaped PTFE junction and solid electrolyte system, it resists fouling and poisoning from media such as sulfides or cyanides. The corrosion-resistant housing and standard 3/4-inch threaded design enable flexible pipeline or protective sleeve installation.
25
核心特點(diǎn)
- 抗污染設(shè)計(jì):環(huán)形聚四氟乙烯液接界不易阻塞,可長(zhǎng)期穩(wěn)定運(yùn)行于含懸浮物或膠體的污水環(huán)境。
- 溫度適應(yīng)性:內(nèi)置溫度補(bǔ)償元件,支持0-80°C范圍測(cè)量,減少溫度波動(dòng)對(duì)pH值的影響。
- 維護(hù)便捷:凝膠電解質(zhì)無(wú)需補(bǔ)充,降低維護(hù)頻率;敏感膜采用特種玻璃材質(zhì),響應(yīng)時(shí)間短(≤10秒)。
- 兼容性:提供BNC接口或Y型接線端子,適配多數(shù)酸度計(jì);電纜可延長(zhǎng)至60米無(wú)信號(hào)衰減。
英文特點(diǎn):
- Anti-fouling Structure: The PTFE junction prevents clogging in wastewater with suspended solids or colloids.
- Temperature Compensation: Covers 0-80°C to minimize pH deviation caused by temperature changes.
- Low Maintenance: Gel electrolyte requires no refilling, while the specialized glass membrane ensures rapid response (≤10 sec).
- Broad Compatibility: BNC or Y-terminal connections fit most pH meters; cables extend up to 60 meters without amplifiers.
612
應(yīng)用場(chǎng)景
適用于印刷電路板廢水、含鉻工業(yè)廢水、生活污水等場(chǎng)景的在線pH監(jiān)測(cè),尤其適合高粘度或含腐蝕性成分的介質(zhì)。電極可搭配流通杯用于高純水行業(yè),或直接浸入反應(yīng)池、管道中連續(xù)工作。
英文應(yīng)用:
Ideal for online pH monitoring in PCB wastewater, chromium-containing effluents, and municipal sewage, especially for viscous or corrosive fluids. It can be paired with flow cells for ultrapure water systems or immersed directly in reactors/pipelines.
37
使用與維護(hù)
建議每周用蒸餾水清洗電極球泡及液絡(luò)部,避免蛋白質(zhì)或有機(jī)硅油脂附著。若玻璃膜出現(xiàn)沉積物,可用稀鹽酸清洗后沖洗。正常使用下電極壽命約1年,惡劣環(huán)境可能縮短周期。
英文維護(hù):
Rinse the bulb and junction weekly with distilled water to prevent protein/silicone contamination. Deposits on the glass membrane can be removed with diluted HCl. Service life is approximately 1 year under normal conditions.
426
GP100W電極(污水處理加溫度補(bǔ)償)
的詳細(xì)介紹GP100W電極/GP-100W
序號(hào)
|
型號(hào)
|
名 稱
|
精度
|
出廠價(jià)¥
|
|
10-62
|
PHS-3C
|
數(shù)顯酸度計(jì)
|
0.01級(jí)
|
2000
|
10-63
|
PHS-4
|
數(shù)顯酸度計(jì)
|
0.02級(jí)
|
1600
|
10-64
|
PHS-2C
|
數(shù)顯酸度計(jì)
|
0.02級(jí)
|
1250
|
10-65
|
PHS-25
|
數(shù)顯酸度計(jì)
|
0.10級(jí)
|
950
|
10-66
|
PHB-1
|
便攜式酸度計(jì)
|
0.01級(jí)
|
880
|
10-67
|
PHB-2
|
便攜式酸度計(jì)
|
0.02級(jí)
|
800
|
10-68
|
PHB-3
|
便攜式酸度計(jì)
|
0.10級(jí)
|
680
|
10-69
|
DDB-11A
|
便攜式電導(dǎo)率儀
|
1.5%F.S
|
920
|
10-70
|
DDB-12A
|
便攜式電導(dǎo)率儀
|
1.0%F.S
|
980
|
10-71
|
PHG-2
|
工業(yè)酸度計(jì)
|
0.10級(jí)
|
3880
|
10-72
|
PHG-3
|
工業(yè)酸度計(jì)
|
0.10級(jí)
|
1480
|
10-73
|
GP100
|
電極(污水處理)
|
|
800
|
10-74
|
GP100W
|
電極(污水處理加溫度補(bǔ)償)
|
900
|
10-75
|
201
|
復(fù)合電極
|
1000
|
10-76
|
232
|
甘汞電極
|
1000
|
10-77
|
231
|
玻璃電極
|
80
|
10-78
|
DJS-1
|
電導(dǎo)電極 黑
|
41
|
10-79
|
DJS-10
|
電導(dǎo)電極 黑
|
41
|
10-80
|
DJS-1
|
電導(dǎo)電極 黑
|
63
|
10-81
|
2G
|
分光光度計(jì)
|
1980
|
10-82
|
7221
|
分柵分光光度計(jì)
|
3880
|
歡迎選購(gòu)GP100W電極(污水處理加溫度補(bǔ)償),我們有優(yōu)勢(shì)的價(jià)格,的服務(wù)!公司承諾,所有商品保證原裝正品,一年保修,終身維護(hù)!業(yè)務(wù)咨詢:021-63515606,QQ客服:332318574
接近開(kāi)關(guān)BI2-M12-AD4X 接近開(kāi)關(guān)BI2-M12-AP6X 接近開(kāi)關(guān)BI2-M12-RP6X 接近開(kāi)關(guān)BI2-M12-RN6X 接近開(kāi)關(guān)BI2-M12-AN6X 接近開(kāi)關(guān)NI2-M8-RZ3X 接近開(kāi)關(guān)NI2-M8-AZ3X 接近開(kāi)關(guān)NI2-M8-RD4X 接近開(kāi)關(guān)NI2-M8-AD4X 接近開(kāi)關(guān)NI2-M8-AP6X 接近開(kāi)關(guān)NI2-M8-RP6X 接近開(kāi)關(guān)NI2-M8-RN6X 接近開(kāi)關(guān)NI2-M8-AN6X接近開(kāi)關(guān)BI1.5-M8-RZ3X 接近開(kāi)關(guān)BI1.5-M8-AZ3X 接近開(kāi)關(guān)BI1.5-M8-RD4X 接近開(kāi)關(guān)BI1.5-M8-AD4X
|