DL-10系列電流繼電器
DL-10系列電流繼電器產(chǎn)品介紹(中文)
DL-10系列電流繼電器是一款電磁式瞬動(dòng)過(guò)電流保護(hù)裝置,專為電力系統(tǒng)二次回路設(shè)計(jì),廣泛應(yīng)用于電機(jī)、變壓器及輸配電線路的過(guò)負(fù)荷與短路保護(hù)場(chǎng)景,作為可靠的啟動(dòng)元件。該系列采用電磁式工作原理,通過(guò)檢測(cè)回路電流變化實(shí)現(xiàn)快速響應(yīng),在1.1倍實(shí)測(cè)動(dòng)作值時(shí)動(dòng)作時(shí)間不超過(guò)0.12秒,2倍動(dòng)作值時(shí)響應(yīng)時(shí)間短至0.04秒,確保設(shè)備安全。產(chǎn)品提供多種型號(hào)如DL-11、DL-12、DL-13等,支持線圈串聯(lián)或并聯(lián)連接方式,整定范圍靈活可調(diào),滿足不同電流等級(jí)的保護(hù)需求。觸點(diǎn)容量方面,能在250V電壓、5A電流的直流有感負(fù)荷電路中穩(wěn)定斷開(kāi)50W功率,且機(jī)械壽命高達(dá)5萬(wàn)次。外殼采用防護(hù)設(shè)計(jì),導(dǎo)電端子可承受2000V交流電壓的介質(zhì)強(qiáng)度測(cè)試,適用于工業(yè)環(huán)境。其結(jié)構(gòu)緊湊,支持板前或板后接線,安裝維護(hù)便捷,是電力保護(hù)系統(tǒng)中常用的基礎(chǔ)元件之一。136
DL-10 Series Current Relay Product Introduction (English)
The DL-10 series current relay is an electromagnetic instantaneous over-current protection device designed for secondary circuits in power systems. It is widely used as a reliable triggering component for overload and short-circuit protection in motors, transformers, and transmission lines. Utilizing electromagnetic operation principles, it responds swiftly to current fluctuations – achieving activation within 0.12 seconds at 1.1 times the set value and 0.04 seconds at double the value. The product line includes variants like DL-11, DL-12, and DL-13, featuring adjustable current ranges through series/parallel coil configurations. With contact capacity of 50W breaking power under 250V DC (5A inductive load) and 50,000 operational cycles, it ensures durable performance. The relay s insulated terminals withstand 2000V AC dielectric tests, while its compact structure supports front/rear wiring for flexible panel integration. Ideal for industrial applications, it combines rapid response with robust construction for essential circuit protection.1418
產(chǎn)品結(jié)構(gòu)與功能特點(diǎn)
該系列繼電器采用透明外殼設(shè)計(jì),便于觀察內(nèi)部動(dòng)作狀態(tài),核心電磁系統(tǒng)包含可調(diào)節(jié)游絲機(jī)構(gòu),通過(guò)旋轉(zhuǎn)刻度盤指針精確設(shè)定動(dòng)作閾值。獨(dú)特的兩組線圈布局允許通過(guò)連接片切換串聯(lián)/并聯(lián)模式,使整定范圍擴(kuò)展一倍。觸點(diǎn)系統(tǒng)包含動(dòng)合與動(dòng)斷組合(如DL-12型帶一常開(kāi)一常閉觸點(diǎn)),采用橋式滑動(dòng)接觸結(jié)構(gòu),確保動(dòng)作過(guò)程中穩(wěn)定導(dǎo)通。產(chǎn)品工作無(wú)需輔助電源,功耗低于7VA,返回系數(shù)≥0.8,可在-25℃至+40℃環(huán)境下穩(wěn)定運(yùn)行。典型應(yīng)用場(chǎng)景包括配電柜、變電站保護(hù)屏及工業(yè)控制系統(tǒng),尤其適用于需要快速切斷故障電流的場(chǎng)合。141720
Technical Features & Construction
Featuring a transparent housing for visual status monitoring, the relay s electromagnetic mechanism incorporates a spiral spring adjustment system for precise current setting. Its dual-coil design enables range expansion via series/parallel switching with terminal links. The contact system (e.g. 1NO+1NC in DL-12 model) employs bridging slides for reliable switching, operating without auxiliary power while consuming <7VA. With ≥0.8 return coefficient and -25℃ to +40℃ temperature tolerance, it suits rapid fault interruption in substation protection panels, switchgear, and industrial control circuits. The modular construction allows vertical panel mounting with 87.5×89mm cutout dimensions, compatible with standard DIN rail accessories.111826
DL-10系列電流繼電器
的詳細(xì)介紹
DL-10系列電流繼電器
電流繼電器 >> DL-10系列電流繼電器 |
|
 |
|
DL-10系列電流繼電器
1、應(yīng)用范圍 |
|
DL-10系列電流繼電器,為電磁式瞬動(dòng)過(guò)電流繼電器,它廣泛用于電力系統(tǒng)二次回路繼電保護(hù)裝置線路中,作為過(guò)電流啟動(dòng)元件。
|
 |
2.主要技術(shù)參數(shù)據(jù) |
|
動(dòng)作時(shí)間:在1.1倍實(shí)測(cè)動(dòng)作值時(shí),動(dòng)作時(shí)間不大于0.12s;在2倍實(shí)測(cè)動(dòng)作值時(shí),動(dòng)作時(shí)間不大于0.04s.
型號(hào)
|
大整定值
|
整定范圍
|
線圈串聯(lián)
|
線圈并聯(lián)
|
功率
|
觸點(diǎn)數(shù)量
|
返回
|
動(dòng)作電流
|
動(dòng)作電流
|
消耗
|
動(dòng)合
|
動(dòng)斷
|
系數(shù)
|
DL-11/12/13
|
0.01A
|
0.0025-0.01A
|
0.0025-0.005A
|
0.005-0.01A
|
≤7VA
|
1
|
1
|
≥0.8
|
DL-11/12/13
|
0.04A
|
0.01-0.04A
|
0.01-0.02A
|
0.02-0.04A
|
≤7VA
|
1
|
1
|
DL-11/12/13
|
0.05A
|
0.0125-0.05A
|
0.0125-0.025A
|
0.025-0.05A
|
≤7VA
|
1
|
1
|
DL-11/12/13
|
0.2A
|
0.05-0.2A
|
0.05-0.1A
|
0.1-0.2A
|
≤7VA
|
1
|
1
|
DL-11/12/13
|
0.6A
|
0.15-0.6A
|
0.15-0.3A
|
0.3-0.6A
|
≤7VA
|
1
|
1
|
DL-11/12/13
|
2A
|
0.5-2A
|
0.5-1A
|
1-2A
|
0.5-1A
|
1
|
1
|
DL-11/12/13
|
6A
|
1.5-6A
|
1.5-3A
|
3-6A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
10A
|
2.5-10A
|
2.5-5A
|
5-10A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
15A
|
3.75-15A
|
3.75-7.5A
|
7.5-15A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
20A
|
5-20A
|
5-10A
|
10-20A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
50A
|
12.5-50A
|
12.5-25A
|
25-50A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
100A
|
25-100A
|
25-50A
|
50-100A
|
≤3.5VA
|
1
|
1
|
DL-11/12/13
|
200A
|
50-200A
|
50-100A
|
100-200A
|
≤3.5VA
|
1
|
1
|
≥0.7
|
|
|
|
● |
觸點(diǎn)容量:在電壓不超過(guò)250V,電流不超過(guò)5A,時(shí)間常數(shù)為5±0.75ms的直流有感負(fù)荷電路中,產(chǎn)品輸出觸點(diǎn)的斷開(kāi)容量為50W。輸出觸點(diǎn)在上述規(guī)定的負(fù)荷條件下,產(chǎn)品能可靠動(dòng)作及返回5×104次。輸出觸點(diǎn)長(zhǎng)期允許接通電流為5A。 |
● |
介質(zhì)強(qiáng)度:產(chǎn)品各導(dǎo)電端子連在—起,對(duì)外露的非帶電金屬部分或外殼之間,能承受2000V(有效值)50Hz的交流電壓歷時(shí)1分鐘試驗(yàn)而無(wú)絕緣擊穿或閃絡(luò)現(xiàn)象。 |
|
3.內(nèi)部接線 |
|
 |
4.外形及開(kāi)孔尺寸 |
|
 |
|
|
|
|